| S.No. |
Description |
UA
- 25 |
UA
- 50 |
UA-100 |
| 1.1 |
Capacity
(acetylene with purity as per IS-30B) Cubic Meter per hour |
25 |
50 |
100 |
| 1.2 |
Raw material required |
|
|
|
| |
1.2.1 |
Process
water (liters/kg of calcium carbide processed) |
8-10 |
8-10 |
8-10 |
| |
1.2.2 |
Calcium
carbide (kg/N.cubic meter of gas) |
4 |
4 |
4 |
| |
1.2.3 |
Calcium
chloride (gms/N.cubic meter of gas) |
50 |
50 |
50 |
| |
1.2.4 |
Cooling
water make-up (liters/N.cubic meter of gas) |
10 |
10 |
10 |
| |
1.2.5 |
Power
(average requirement) |
12KW |
15 KW |
28KW |
| |
1.2.6 |
Purifying
mass (gas plus acid absorption mix per cum of gas) |
15 gms/N.Cum + 4 gms |
15 gms/N.Cum + 4 gms |
15 gms/N.Cum + 4 gms |
| |
1.2.7 |
Instrument/Process
air |
70
liters/minute |
70
liters/minute |
100
liters/minute |
| |
1.2.8 |
Acetone |
As required |
As required |
As required |
| |
1.2.9 |
Hydraulic
oil (for screw feed system) |
Equivalent to SAE
- 30 |
Equivelent to SAE
- 30 |
Equivalent to SAE
- 30 |
| |
1.2.10 |
Lubricating
oil (for compressor) |
Hylube
HDX-40 |
Hylube
HDX-40 |
Hylube
HDX-40 |
| 1.3 |
Space required (abt) |
|
|
|
|
| |
1.3.1 |
Process
Area |
70 Sq.M. |
110 Sq.M |
150 Sq.M |
| |
1.3.2 |
Carbide
Storage Area |
75 Sq.M. |
112 Sq.M |
175 Sq.M. |
| |
1.3.3 |
Cylinder
filling area |
40 Sq.M. |
60 Sq.M |
100 Sq.M. |
| |
1.3.4 |
Cylinder
storage area (depending upon cylinder inventory) |
100 Sq.M. |
160 Sq.M |
200 Sq.M. |
| |
1.3.5 |
Lime slurry
disposal area |
100 Sq.M. |
180 Sq.M |
250 Sq.M. |
| |
1.3.6 |
Free space
around the plant (on all sides) |
16 M |
18.5 M |
20 M |
| |
1.3.7 |
Acetone
godown |
12 Sq.M. |
20 Sq.M |
30 Sq.M. |